Technician Reference

Pulsed 500 Watt — Specs & Setup

HTCM500 · SEAGULL3™

Pulsed MOPA fiber system for precision and delicate work — thin metal, wood, and stone. Low heat input protects the substrate.

Precision Laser Solutions 500W pulsed MOPA laser cleaning machine
Paste into your favorite AI for setup guidance.

Machine Specifications

SpecificationValue
ModelHTCM500 (SEAGULL3™)
Laser typePulsed fiber (MOPA)
Laser sourceJPT MOPA pulsed fiber
Max average power500 W
Wavelength1064 nm
Max pulse energy15 mJ (range 1.5–15 mJ)
Pulse width2–500 ns (JPT MOPA, adjustable)
Pulse frequency1–4,000 kHz (adjustable)  full 15 mJ/pulse up to ≈ 33 kHz; per-pulse energy drops at higher rates
Cleaning modes8 (single-axis) / 13 (dual-axis)
Scan width0–5.7 in (0–145 mm)
Max scan speed98.4 ft/s (30 m/s ≈ 30,000 mm/s)
Fiber cable length32.8 ft (10 m), customizable
CoolingAir-cooled
Input power220 V / 50 Hz, 1-phase (110 V / 60 Hz optional; universal 110–220 V, 50–60 Hz)
Whole-machine draw2.5–3 kW (≈ 11–14 A @ 220 V)
Cleaning gun weight< 3.3 lb (< 1.5 kg)
Machine weight110 lb (50 kg)
Machine dimensions19.5 × 13.9 × 23.9 in (495 × 353 × 608 mm)
Operating temperature41–104 °F (5–40 °C)
Operating humidity≤ 80%
Cleaning rate≈ 161 ft²/h @ 0.8 mil paint or rust (15 m²/h @ 20 µm)
CertificationsCE, FDA
Warranty2-yr laser source / 1-yr machine
⚠ Class 4 laser. Follow ANSI Z136.1 and OSHA requirements, use EN207-rated 1064 nm eyewear and fume extraction, and operate only under a qualified Laser Safety Officer. Verify settings on a test coupon and never exceed the machine's rated limits.